5.12.3 Place new battery pack
Joint the cord of the new lithium battery pack with the
power supply wire in the battery case. Verify that the two
are securely connected. First put the cord into the side hole
in the battery case; then place the battery pack; finally,
close the cover of the battery case which is at the bottom of
the Fusion Splicer.
6

6.1 Power Supply

Power does not turn off when pressing
Press
and hold the key until the LED color changes from red to
green. Release
Few splices can be made with a fully charged battery pack
z If the power saving function is not enabled, battery power degrades
faster.
z The battery pack uses chemical reaction. The capacity decreases at
low temperature, especially at lower than 0 degree.
z At high altitude, the arc discharge current is increased. In this
condition, battery power degrades faster due to large power
consumption.
z The AC/DC adapter is not the model supplied by the Company, or
the charging time is not long enough.
"CHARGE" LED on AC adapter blinks during battery recharge
z Atmospheric temperature is too high (more than 50 degrees C), or
the battery pack is charged under exposure to sunlight.
z The battery pack has a fault or has reached the end of its service life.
Install a new battery pack. If the LED blinks again after install,
contact your nearest sales agency.
The AC/DC adapter is not the model supplied by the Company.

6.2 Splicing Operation

Inconsistent splice loss / High splice loss
z Clean the V-grooves, fiber clamps, wind protector mirrors, and
objective lenses. Refer to [Check an Maintenance] (chapter 5)
z Replace electrodes, please refer to [Replace Electrodes] (chapter 5.5)
z If the fiber is bending, bending part should be upward when placing
the fiber.
z The splice loss varies according to the cleave angle, arc conditions
and fiber cleanliness.
z If the splice loss is still too high or inconsistent after performing the
above-mentioned remedies, contact your nearest sales agency.