[Maintenance menu 2]. Press
Press
to execute the check process. The message "Please wait
while checking is processed" is displayed in the lower part of the screen.
<3> In [Dust Check] operation interface, press
screen or Y screen to perform checking. Press
perform checking in another screen.
<4> A message appears on the Dust Check screen indicating that
"X(Y) image check is approved". Press
previous operation interface. Normal fusion splicing can be
performed now.
z If message appears on the screen indicating that "image is dirty" after
Dust Check, clean the wind protector mirrors and objective lenses and
redo [Dust Check]. If the dirt or dust still remains, contamination may
have entered the optical path. Contact your nearest sales agency.
5.9 Maintenance of blade

5.9.1 Cleaning Fiber Cleaver

<1>If the circular blade or elastomeric clamp pads of the fiber
cleaver become contaminated, the cleaving quality could
degrade. This may lead to fiber surface or end-face
contamination, resulting in higher splice loss.
<2> Clean the circular blade or elastomeric clamp pads with cotton
swab soaked with alcohol.

5.9.2 Rotating Cleaver Blade

If the cleaver does not cleave properly, rotate the blade 1/16 of a turn
to replace the worn out blade position with a sharp blade position. To
rotate the blade, do the following:
<1> Use a hexed-angle spanner provided by the cleaver to loose the
hexed-angle screw.
<2> Lean the cleaver to an angle of 45 degree. Use a hexed-angle
spanner provided by the cleaver or other pointed items to insert
into operation hole. Rotate the blade clockwise to one to sixteen
valid position marks.
<3> Tighten the blade lock screw.
Do not touch the edge during the installation.

5.9.3 Blade Height Adjustment

In normal condition the blade height need not to be adjusted. If
anomaly occurs, perform the following steps to verify if it is due to blade
error.