_____________________________________________________________________
of heater.
Details of the heating parameters are described in the following
table.
Parameter
Sleeve type
Length type
Heater Control
Heat Time
Heat Temp
Finish Temp
3.2.4
Creating heating mode
<1> The default of heating mode
When the machine left the factory, there are 8 Splice Modes within
it, that is, there are 8 heating modes, which are numbered from 1 to 8;
others are all displayed as [BLANK]. The user can increase and copy
Splice Modes into the (BLANK).
©Copyright Abacanto Digital SA.
Sets sleeve type. List of all heating modes are displayed.
Select a mode in the list and this is copied to a
user-programmable mode. (Note: Select and confirm the
"BLANK", then the heating mode is a "blank file")
Set length type. The length type list is displayed on the screen.
Choose a mode in the list and the mode can be copied to user
adjustable mode.
Heater control "open" or "close" option, confirm and return to
the [Splice Mode menu].
Sets heating time from the beginning to the end (cool-down
completion).
Sets heating temperature. In the case that Ny coated fiber is
used with 8mm cleave length, the Ny coating may melt if
[Heat Temp] is over 190 degrees
Sets the finish temperature.When heater approaches this
temperature, the buzzer beeps announcing the sleeve is cooled
down and is ready to be taken out of the heater.
Manual de usuario AD300
AD Instruments
Description
127