_____________________________________________________________________
<1> Loosen the hexed-angle screw. Then use the spare 1.5mm
hexed-angle spanner which is at the bottom of cleaver to insert
into the hole in the bottom of cleaver. Finally the hexed-angle
screw is loosened.
<2> It is recommended to rotate clockwise the adjusting shaft at the
middle of the tool post about half a scale or less. The pressure
will increase the quality of the cut end face.
<3> Tight the screw.
<4> Repeat the previous operation until the blade is adjusted to a
proper position.
5.9.4 Blade Replacement
After the circular blade has been raised 3 times and rotated through
all positions, it needs to be replaced. Contact your splicer distributor.
In order to maintain the splicing quality of the splicer, periodical
inspection and cleaning are recommended.
5.10 Set Calendar
This function sets the date and time in the calendar
incorporated in the splicer.
<1> In the Application Menu, press
and move the cursor to select the [Calendar Set]
<2> Press
to enter [Set Calendar] interface.
Press
or
changed. Press
<3> After completion of calendar setting, press
are stored.
5.11 Heater/Battery/Environment
©Copyright Abacanto Digital SA.
and move the cursor to select the item to be
to adjust the value.
Manual de usuario AD300
AD Instruments
or
. The date and time
174