Fusion Operation; Checking Of Fiber Cutting Angle And Fiber End Face - ADInstruments AD300 Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

_____________________________________________________________________
move the cursor to select the "Blank". Double press
and the copied splice parameter file numbered "××" (such as
Number"16") is deleted, that is, the file is changed back into
blank Splice Mode (BLANK).
Note3: The user may also modify some parameters of the newly
copied splice file numbered "××" (such as Number"16").
Refer to 4.1.2 - <2> extract and edit the Splice Mode.

4.3 Fusion operation

AD300 has installed an image processing system to observe the
fiber. However, in certain circumstances, the image processing
system might not have found error in fusion. Therefore, to achieve
good fusion results, we have to carry out visual inspections on
optical fiber through the display. The following describes the
standard fusion steps.

4.3.1 checking of fiber cutting angle and fiber end face

<1> After two optical fibers being put into fusion
splicer, two optical fiber will move at the same
direction, After discharge and cleaning, fiber
stops at an setted position. Then check the
quality of cutting angle and the end face of fiber.
If the measured fiber cutting angle is greater than the set limits, or
checked out fiber end face has burrs, buzzer will ring and at the same
time, the display will show an error message to warn the operator. At
the same time, the fusion process will be suspended. The user may
reset the limit of cutting angle and the quality of the end face of
©Copyright Abacanto Digital SA.
Manual de usuario AD300
AD Instruments
,
left side cutting perspective
160
right side cutting
perspective

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido