Especially when the splicer is moved from lower altitudes to higher
altitudes, it takes time for the arc power to stabilize. In this case,
stabilizing electrodes will expedite the process of making the arc
power stable.
Operation Procedure
<1> Execute [Stabilizing Electrodes] in [Maintenance Menu 1].
<2> Select the [Stabilize Electrodes].
<3> Press
or
of "Arc power"
the default value is recommended , "Arc Count"(the average value
is 20)
<4> Select "execute". Press
performed according to the parameters which are set in <3> of this
section.
<5>To achieve best arc discharge, execute
three times after Stabilizing Electrodes is completed.

5.7 Clearing Arc Count

This function enables the stored number of arc discharges to be reset.
<1> In [Maintenance menu 1], Press
select [Arc Count Clear]
<2> Press
. Then a screen appears displaying a warning message "arc
count is to be cleared". Press

5.8 Dust Check

The splicer observes fibers through image processing. Dust or
contaminants on the cameras, lenses and wind protector mirrors disturbs
normal observation of fibers and may result in improper splicing. This
function checks the optical path for the presence of contaminants and
indicates the position.
5.8.1 The Fusion Splicer has dust check function, which allows the user
to check the optical path for dust or dirt and judge whether they
disturb fiber observation. If contamination exists, this function
indicates the location.
5.8.2 Operation Procedure
<1> Before the start of the test, remove the fibers from the splicer.
<2> In [Splice Mode] menu, press
©Copyright Abacanto Digital SA.
and move the cursor to select and set the parameters
the default value is recommended , duration
to confirm. Stabilizing Electrodes is
Manual de usuario AD300
AD Instruments
discharge calibration for
or
and move the cursor to
to execute clear function.
or
to enter