Signal destinations for STW2_BM for telegram 220
Signal
Meaning
STW2.0
Command data set selection CDS bit 0
STW2.1
Reserved; bit must always be set to 0
STW2.2
Command data set selection DDS bit 0
STW2.3
Command data set selection DDS bit 1
STW2.4
Reserved; bit must always be set to 0
STW2.5
1 = Bridge ramp-function generator
STW2.6
Reserved
STW2.7
1 = Speed controller integration value set
STW2.8
1 = Enable droop
STW2.9
1 = Enable speed controller
STW2.10
Reserved
0 = Speed-controlled operation
STW2.11
1 = Torque-controlled operation
STW2.12
Reserved
STW2.13
Reserved
STW2.14
Reserved
STW2.15
Controller sign-of-life toggle bit
<1> Interconnection is not inhibited.
1
2
DO: DC_CTRL
PROFIdrive - STW2_BM control word sector metal interconnection
p0820[0] = r2093.2
<1>
p0821[0] = r2093.3
<1>
p50641[0] = r2093.5
p50695[0] = r2093.7
p50684[0] = r2093.8
p0856[0] = r2093.9
<1>
<1>
p50687[0] = r2093.11
<1>
<1>
<1>
p2081[15] = r2093.15
3
4
Interconnection
Function diagram
Inverted
parameter
p0810 = r2093.0
[8560.3]
[8565.3]
<1>
[8565.3]
<1>
[3152.1]
[6815.1]
[6805.4]
[2580.3]
<1>
<1>
[6830.2]
<1>
<1>
<1>
[2472.1]
5
6
fp_2426_13_eng.vsd
28.08.18 V01.05.00
PROFIdrive sampling time
7
8
Function diagram
- 2426 -
SINAMICS DCM