Descargar Imprimir esta página

Siemens SINAMICS DCM Manual página 748

Ocultar thumbs Ver también para SINAMICS DCM:

Publicidad

TM15DI_DO
TM31
TM150
<1> Using the two connector-binector converters at [2472], the bits from 5 of the send words can be interconnected with any binectors.
<2> Physical word values are inserted in the telegram as referenced variables.
(Telegram content = 4000 hex if the input variable has the value p200x).
<3> Only for DO CU_DC and CU_DCP.
<4> Only for SINAMICS DCM.
1
2
DO: CU_DC, CU_DCP, TM15DI_DO, TM31, TM150
PROFIdrive - IF1 send telegram, free interconnection via BICO (p0922 = 999)
IF1 diag send word
r2053[0...24]
<1>
...
...
p2051[0]
(0)
PZD send word 1
p2051[1]
(0)
PZD send word 2
p2051[2]
(0)
PZD send word 3
p2051[3]
PZD send word 4
(0)
p2051[4]
(0)
PZD send word 5
p2051[5]
<3>
(0)
PZD send word 6
p2051[6]
<3>
(0)
PZD send word 7
p2051[21]
<3>
(0)
PZD send word 22
p2051[22]
<3>
(0)
PZD send word 23
p2051[23]
<3>
(0)
PZD send word 24
p2051[24]
<3>
(0)
PZD send word 25
<2>
3
4
PROFIdrive
send telegram
Header
Drive object 1
Drive object 2
.
.
.
Drive object n
.
.
.
<3>
Drive object m
<3>
Trailer
PROFIBUS
PROFINET
<3>
USS
<4>
<3>
<3>
<3>
5
6
fp_2483_70_eng.vsd
14.11.18 V01.05.00
PROFIdrive sampling time
7
8
Function diagram
- 2483 -
SINAMICS DCM/DCP

Publicidad

loading