The machine must not be operated in explosive atmosphere.
ELECTRICAL AND PNEUMATIC HOOK-UPS
The electrical hook-up and the adaption of the electric motor to the mains voltage in the
place of installation must be carried out only by a qualified electrician.
The electrical supply must be suitably sized in relation to:
- absorbed power specifications indicated on the machine dataplate.
- the distance between the machine and the power supply hook-up point, so that voltage
drops under full load do not exceed 4% (10% in the case of start-up) below the rated
voltage specified on the dataplate.
The user must equip the machine with the following:
- a dedicated power plug in compliance with the relevant electrical safety standards.
- a type A and B suitable circuit-breaker (residual current set to 30 mA) on the mains
connection;
WARNING: only a type A and B differential security breaker of the specified kind will be
tripped correctly in response to all the failure currents which may occur on the machine.
- power line fuses in accordance with specifications in the main wiring diagram of this manual.
- a suitable earthing system installed on the workshop mains line
To prevent unauthorised use of the machine, always disconnect the mains plug when the
machine is not used (switched off) for extended periods of time.
If the machine is connected directly to the power supply by means of the main electrical
panel and without the use of a plug, install a key-operated switch or suitable lock-out device
to restrict machine use exclusively to qualified personnel.
For correct operation of the machine the compressed air supply line must provide a pressure
range from a minimum of 8 bar to a maximum of 16 bar.
NOTE
The machine is equipped with a pressure regulator set at 10 bar (standard machine operation).
If you are working with easily deformable rims (motor cycle wheels for example) we recommend
lowering the pressure temporarily to 7 or 8 bar.
For correct and safe operation of the machine it must be connected to an efficient
grounding circuit.
line or other makeshift system.
Before making the electrical and pneumatic hook-ups, make sure that the machine is configured
as described below (Fig. 8):
pedal 8 in "pressed right down" position
tower 4 vertical (not tilted)
pedal 7 in "pressed right down" position
ATTENTION
WARNING
ATTENTION
NEVER connect the ground wire to a gas pipe, water pipe, telephone
7