EN
Possible cause
The female coupler is faulty.
8
Maintenance
8.1
General
For standard installation instructions, refer to the Service & Support section of the Holmatro website.
Proper preventive maintenance of the equipment preserves the operational safety and extends the life
of the equipment.
WARNING
When performing maintenance activities, always comply with the relevant safety regulations.
Wear the prescribed personal protection equipment.
8.1.1
Dangerous substances
WARNING
Used or leaked fluids, and any other products consumed during the activities, must be
collected and disposed of in an environmentally responsible way.
8.2
Maintenance materials
/i
Application
Steel parts
Hydraulic couplers
Hydraulic oil
Engine oil
8.3
Maintenance schedule
This schedule is an average. Depending on the intensity of use of your equipment, Holmatro can
provide a specific maintenance schedule for you.
/i
Object
General
42
Type of maintenance material
WD-40 preservative oil
Tectyl ML from Valvoline (long term preservation)
WD-40 preservative oil
ISO-L HV VG 15/36
10W-30
Action
Check
916.219.173_005
Solution
Have it repaired by a Holmatro Certified
Technician.
Time interval
x
Amount
As required
As required
As required
As required
As required
x
IPU-M