WARNING
Unsafe Operation Hazard
Failure to lock the outrigger in the transport position could
result in death or serious injury. Be sure the outrigger is
locked in the transport position.
7. Repeat for the remaining outriggers and stabilizer
jacks.
12
E
A
B
C
Adjusting The Tower Lights
WARNING
Burn Hazard
Adjusting the tower lights while the lights are on could
result in serious injury. Turn the lights off and wait 10
minutes to cool before adjusting the tower lights.
Note: The tower lights must be adjusted to the preferred
work angle before raising the light tower.
To adjust for operation
Hydraulic (vertical) towers – LED
1. Set the light bar to the preferred work angle..
A. Pull the park pin (A, Figure 13) and rotate 90°
to unlock the light bar.
B. Rotate the light bar to the preferred work angle.
C. If the light bar rotates loosely or does not
remain in the preferred work position:
F
D
G
•
Remove the cap plug from the center of
the light bar.
•
Tighten the pivot nut until desired
resistance is achieved.
•
Replace the cap plug.
2. Set the tower arms to the preferred work angle.
A. Loosen the adjustment nut (B, Figure 13) on
each tower arm.
B. Pull the park pin (C, Figure 13) and rotate 90°
to unlock the tower arm.
C. Rotate each tower arm to the preferred work
angle.
D. Tighten the adjustment nuts.
3. Set each individual light fixture to the preferred work
angle.
•
Yoke center pivot (D, Figure 13) - adjusts the
horizontal angle of each individual light fixture.
Grasp the sides of the yoke to adjust.
•
Fixture pivots - adjust the vertical angle of each
individual light fixture. Loosen the locking clasp
(E, Figure 13), move the light fixture up or
down to adjust, then tighten the locking clasp.
13
C
D
A
Hydraulic (vertical) towers – metal halide
1. Set the light bar to the preferred work angle..
A. Pull the park pin (A, Figure 14) and rotate 90°
to unlock the light bar.
B. Rotate the light bar to the preferred work angle.
C. If the light bar rotates loosely or does not
remain in the preferred work position:
•
Remove the cap plug from the center of
the light bar.
•
Tighten the pivot nut until desired
resistance is achieved.
•
Replace the cap plug.
E
B
en
English
19