Descargar Imprimir esta página

Milwaukee Allmand NIGHT-LITE PRO II Manual Del Operario página 25

Publicidad

Idiomas disponibles

Idiomas disponibles

24
A
25
C
A
26
A
27
A
C
B
F
E
B
D
E
D
B
C
B
C
28
A
Power is supplied to the outlets when the engine is
running and the main breaker (A, Figures 24 through 28)
is ON.
Each outlet is protected by a dedicated circuit breaker. If
a breaker trips:
1. Disconnect the load from the outlet.
2. Turn off the tower lights or shut off the engine.
3. Wait 10 minutes for the generator to cool down.
4. Correct the load problem.
5. Start the engine or turn on the tower lights.
6. Reset the breaker.
Note: Be sure to also check the GFCI breaker on the
GFCI outlet (if equipped), and reset if necessary.
7. Reconnect the load.
8. If the problem persists, see Troubleshooting.
Shutting Down The Unit
1. Shut down the tower lights. See Operation -
Operating The Tower Lights.
2. Shut down the engine. See Operation - Operating
The Engine.
3. Lower the light tower. See Operation - Raising And
Lowering The Light Tower.
4. Adjust the lights to the transport position. See
Operation - Adjusting The Tower Lights.
WARNING
Burn Hazard
Handling hot light fixtures could result in serious injury.
Allow lights to cool before handling, or use heat- resistant
gloves.
5. Retract the stabilizer jacks and outriggers. See
Operation - Using The Outriggers & Stabilizer
Jacks.
6. The unit is now ready for transport. See
Transporting.
B
C
en
English
25

Publicidad

loading