6.3.2 Nulling the measurement system

The measurement system may only be nulled once the lift is in its lowest position.
Access to the DIP switch may only be done by a trained, authorised specialist.
d)
There may not be any vehicles on the lift.
e)
Both rails must be in the lower position.
f)
Open the control cabinet
g)
Check that both rails are in the lower position.
h)
If needed, push the "Lower" button until both rails are in the lowest position.
i)
DIP switch 5 remains in the "on" position.
j)
Afterwards, place the DIP switch 7 to the "on" position.
k)
Wait for one second then place DIP switch 7 to the "on" position. A null must show in the
display.
l)
Close the control cabinet doors
m)
Check lift function then do a processor reset, see sequence in Section 6.3.3 Resetting the
processor.

6.3.3 Resetting the processor

n)
DIP switch number 5 must be at the on position, the reset of the DIP switch to the off
position.
o)
Push the processor reset button