P R O G R A M M E E D I T O R
8
Programme editor
E N
8.1
CVTL commands
The firing programmes are programmed using
CVTL commands. These commands have the fol-
lowing meaning:
Command
A
C
L
T and an at least two digit
number
T and a single digit number
T0xx.Cxxxx
T(x)xx.Cxxxx, (x) <> 0
T0xx.Axxxx
T(x)xx.Axxxx, (x) <> 0
T(x)xx.Lx
Tab. 3
For better clarity, two successive commands can
be separated with a space.
On confirmation of the entry, the syntax is
checked. If the entered command line contains an
error, a warning message is displayed. The com-
mand line must be corrected.
68
Meaning
defines the temperature in °C on the insulation table (Autodry)
defines the temperature in °C in the firing chamber (degree Celsius)
L defines the lift position (Lift):
_ L0 = Lift completely down
_ L9 = Lift completely up
defines the time in seconds (Time)
defines the number of signal tones (beeps)
defines a temperature ramp via temperature gradient:
_ T defines the ramp in °C/min,
_ C defines the final temperature in °C in the firing chamber
defines a temperature ramp:
_ T defines the time in seconds,
_ C defines the final temperature in °C in the firing chamber
defines a temperature ramp via temperature gradient:
_ T defines the ramp in °C/min
_ A defines the final temperature in °C on the insulation table
defines a temperature ramp:
_ T defines the time in seconds
_ A defines the final temperature in °C on the insulation table
defines a lift ramp:
_ T defines the time in seconds
_ L defines the final lift position
CVTL commands