Operating manual - English
•
Enter the new code to be cut.
•
[ENTER] to continue with a new code.
•
[STOP] to end the operation.
5.6
C
ALIBRATIONS
Below are described all the steps required for calibration.
Choose the function from the main menu by placing the cursor on "3 - Calibrations".
The machine has a 'self-calibration' system that uses the tracer point or special templates when
necessary.
The clamps and decoder must be gauged before use.
In the situations shown in the table it may be necessary to carry out one or all gauging operations again
for the clamps and decoder.
This operation is semi-automatic and requires close attention to the instructions listed below.
EVENT
Electronic
board replacement
Clamp replacement
(with a new one of the same type)
Cutter replacement
(with a new one)
Decoder replacement
(with a new one)
5.6.1
Automatic calibration of clamp
Below is a description of all the steps necessary for calibration.
Choose the function from the main menu by placing the cursor on "3 - Calibrations".
Press ENTER, the display will show:
Select "1 - Clamps".
The display will show:
The 3 key-positioning jaws (A - B - C) must be gauged.
34
N e w c o d e ?
= K 0 0 2
( K 0 0 1 - N 7 1 8 )
[ E N T E R ]
0 - D e c o d e a n d C o p y
1 - I n s e r t t h e C u t s
2 - L i s t o f C o d e s
3 - C a l i b r a t i o n
CLAMPS
YES
YES
NO
NO
1 - C l a m p
2 - C u t t e r
3 - T r a c e r p o i n t
C l a m p
1 : A
2 : B
3 : C
Copyright Silca 2006
> >
CALIBRATIONS
CUTTER
DECODER
YES
YES
YES
NO
SI
NO
NO
NO
TRI-CODE H.S.