Operating manual - English
- close the protective shield. Press START,
- start automatic calibration of the clamp by electrical contact.
the display will show:
At the end of the operation the following message will appear (e.g.):
Press [ENTER] to save the data automatically adjusted.
Attention: if the [STOP] key is pressed the new calibrations will be lost and only the previous calibrations will
remain valid.
- if this is not so, the display will show an error message:
In this case the procedure MUST be repeated, carefully following all the steps described; in particular
check the positioning of the clamp (Ch. 4.4, page 18).
Wrong positioning can throw out the calibration.
Note: the calibrations will be accepted only if the variations remain within a range of -40 or +40 hundredths of a mm
(-0.0157" / +0.0157").
• CLAMP C
With the pointer on "2", press ENTER; the display will show the message:
The X and Y values can be different from "00" due to previous calibration.
Before calibration, check that there are no keys on the clamp.
Press START, the display will show:
Attention: calibration of the CLAMPS (A-B-C) MUST BE CARRIED OUT with the TRACER POINT U111 fitted in
the place of the cutter.
Attention: loosen the lever (N) and turn the (O) dial to position 10.
Remove the H101 cutter and fit the U111 tracer point/decoder, checking that the tracer point is not
damaged, bent or split (Ch. 4.6 "Changing the cutter and/or the tracer point", page 19).
Loosen the (F1) handle (fig. 31) by one turn and pull the anatomic grip (F2) towards the operator. This
releases the clamp so that it can slide. Release the anatomic grip, move the clamp manually and the
positioning device will lock the clamp into the clamp reference notch. When the clamp is in position
(Clamp C) tighten the (F1) handle.
C l a m p : B
D e t e c t i o n
i n p r o g r e s s !
C l a m p : B
X = - 0 2
Y = + 0 1
S a v e d a t a ?
N o = S T O P
Ye s = E N T E R
E x c e e d e d s e t t i n g
t o l e r a n c e l i m i t !
X = - 0 2
Y = + 4 2
S e e o p e r a t i n g m a n u a l .
C l a m p : C
A d j u s t m e n t :
X = + 0 0
Y = + 0 0
T o c a l i b r a t e
[ S T A R T ]
C l a m p : C
T r a c e r : U 1 1 1
S e e o p e r a t i n g m a n u a l .
[ S TA R T ]
Copyright Silca 2006
TRI-CODE H.S.
37