Operating manual - English
• CLAMP A
Place the pointer on "1", press ENTER, and the display will show the message:
The X and Y values can be different from "00" due to previous calibration.
Before calibration, check that there are no keys on the clamp.
Press START; the display will show the message:
Loosen the (F1) handle by one turn and pull the anatomic grip (F2) towards the operator. This releases
the clamp, which must be slid to the right. Release the anatomic grip, move the clamp manually and the
positioning device will lock the clamp in the clamp reference notch. When the clamp is in position (Clamp
A) tighten the (F1) handle.
Turn the (F) knob to the left.
Fit the Z22 template into jaw A (fig. 29) so that it lies flat against the clamp with the area marked A up
against Stop 2 (to do this, turn the Stop1 plate to the left and downwards).
Secure the Z22 template by turning the (F) knob to the right.
Z22
Fig. 29
press ENTER; the display will show the message:
Attention: calibration of the CLAMPS (A-B-C) MUST BE CARRIED OUT with the TRACER POINT U111 fitted in
the place of the cutter.
Attention: loosen the lever (N) and turn the (O) dial to position 10.
Remove the H101 cutter and fit the U111 tracer point, making sure the tracer point is not damaged, bent
or split (Ch. 4.6 "Changing the cutter and/or the tracer point", page 19).
- close the protective shield. Press START.
- start automatic calibration of the clamp by electrical contact.
- the display will show:
At the end of the operation the following message will appear (e.g.):
C l a m p : A
A d j u s t m e n t :
X = + 0 0
Y = + 0 0
To c a l i b r a t e
[ S TA R T ]
C l a m p : A
T e m p l . : Z 2 2 - A
P o s . : 2
S e e o p e r a t i n g m a n u a l
[ E N T E R ]
F2
F1
C l a m p : A
T r a c e r : U 1 1 1
S e e o p e r a t i n g m a n u a l
[ S TA R T ]
C l a m p : A
D e t e c t i o n
i n p r o g r e s s !