The ASP GLOSAIR™ 400 Cartridge is intended to be used only in combination with the ASP
GLOSAIR™ 400 System for decontamination of surfaces in environments such as hospitals,
healthcare, commercial and industrial facilities.
The ASP GLOSAIR™ 400 Cartridge must be used according to the instructions described in the
User Manual supplied with the ASP GLOSAIR™ 400 System.
APPLIcAtIoN
The ASP GLOSAIR™ 400 System releases 6ml/m³ of solution from the ASP GLOSAIR™ 400
Cartridge into the room with an average output of 30 ml/ minute. The required contact time for
effective decontamination after the complete diffusion is two hours.
ActIVE INGrEDIENts
5 - 6% hydrogen peroxide and 50 ppm silver cations.
DIrEctIoNs for usE
Step 1
:
Align the red dot on the ASP GLOSAIR™ 400 Cartridge with the red dot on the ASP
GLOSAIR™ 400 System. Insert the ASP GLOSAIR™ 400 Cartridge into the cartridge
chamber of the ASP GLOSAIR™ 400 System.
Step 2
:
Wait for the ASP GLOSAIR™ 400 Cartridge to be identified by the system. If the dentification
or rejection message does not appear, repeat step 1. If the ASP GLOSAIR™ 400 Cartridge
identification fails, use another cartridge. Identification fai re could be caused by an expired
product or an incompatible product.
Step 3
:
Turn the ASP GLOSAIR™ 400 Cartridge clock-wise and lock into place. Ensure the red dot on
the cartridge is aligned with the lock symbol on the ASP GLOSAIR™ 400 System.
Step 4
:
Remove the air vent sticker.
Step 5
:
Wait for the solution from ASP GLOSAIR™ 400 Cartridge to flow into the tank.
Step 6
:
The display panel on the ASP GLOSAIR™ 400 System will show the main menu screen once
the tank is filled.