5-7-3-3
Field P/O Measurement Mode (field payout rate measurement mode)
The percentage of coins dispensed to players (dispensed to the coin tray) to all
coins inserted and coins discaharged from the coin hopper (C) in this game is
called the "field payout rate".
This mode is used to measure the field payout rate in a simplified manner.
1.
Select FIELD P/O MEASUREMENT MODE from the I/O Test Menu screen.
The following screen is displayed.
After the measurement is completed, press the Enter switch. The display
will return to the I/O TEST MENU.
PAYOUT SOLENOID
HOPPER(C)
COUNT CLEAR
SELECT SW:CHOOSE
(a)
Turns the payout solenoid ON/OFF
(b)
Turns the Coin Hopper (C) ON/OFF. Displays the number of discharged
coins.
(c)
Clears the count of the coins discharged by Coin Hopper (C). When the
Enter switch is pressed, the display prompts for the input "YES"" or "NO".
NO (Count not cleared)
YES (Count cleared)
It is recommended to measure the payout rate by using this mode following
installation or any changes to the playfield, or levelling of the machine.
The payout rate may change suddenly in a new machine due to wearing-in,
caused by coins, in the initial period of operation and the natural stacking of coins
on the playfield. To maximise income, it is very important that following the
installation of this game, the payout rate is checked regularly, and when
necessary adjusted.
FIELD P/O MEASUREMENT MODE
OFF
OFF
0
ENTER SW:ENTER
Page 65
(a)
(b)
(c)