Remove the measurement cylinder under the front leg and, as
shown in the figure, place the measurement cylinder with 27mm
(M) height below the front left leg of the calibration stand.
Checking the inclination to the left
After actuating the button, the measured values are
saved.
Now, remove all the measurement cylinders under the legs of the
calibration stand.
After actuating the button, the measured values are
saved. After the end of the measurement process, the
program asks for the user data. To maintain documen-
tation, it is also a good idea to enter the available serial
numbers.
On actuating the Enter key (E
The starting screen is displayed again.
9.6
Head Cross-Check
Press the following buttons for Head Cross-Check:
,
and
Then you get a description how Head Cross Check is working:
- Drive the vehicle onto the turntable supports and slip plates.
- Fit the pedal depressor on the brake.
- Remove the support and slip plate safety pins.
- Apply the sensors to the wheels, fitting the front sensors on the
rear axle and vice-versa.
- SET THE THRUST ANGLE AT ZERO by turning the steering
wheel then fit the steering clamp.
- When the values measured are stable press "Continue".
- Swap the sensors on the wheels, fitting the front sensors on the
front axle and vice-versa.
- If differences > 5'(0.08°) are found the wheel aligner must be
calibrated.
- Delete Historic Record ?
- If the results obtained are greater than 5'(0.08°), a measure-
ment error has been made.
- REPEAT THE MEASUREMENT
- If the previous results are also repeated during the second
measurement, calibrate the system.
1 689 979 873N
19.03.2010
E
E ) the calibration is complete.
E
E
.
- After calibration, make a measurement for comparison.
- If the results obtained are still greater than 5'(0.08°), contact
the authorised service centre.
10.
Smart Card upgrade
For the aligner there are several upgrades as special accessories
availlable:
- 1 987 009 AS1N animated pictures: the assisting pictures how
to adjust a car are animated
- 1 987 009 AS2N Multilink procedure: to do an alignment
procedure according to VAG requirements. To do this VAG
procedure additional accessories are necessary (VAG special
tools like VAG 1952, 1 987 009 A25N)
- 1 987 009 AS3N Mercedes-Benz: to do an alignment proce-
dure according to VAG requirements. To do this VAG procedu-
re additional accessories are necessary (MB toe pressure bar,
1 987 009 A01N, adapter for MB 5-hole or MB 4-hole rims, 1
987 009 A04N or A05N as well as the MB Romess supplier
through the MB organisation)
- 1 987 009 AS7N ASANetwork: that the software is able to
communicate with the network manager from ASA
- 1 987 009 AS8N Shim-Software: with pictures and advices
how to use the Shim discs
These secondary upgrade cards have to be installed after the
software has been installed:
- Insert the SmartCard that was supplied into slot „B" of the USB
interface. When inserting the card, ensure that the contacts go
first into the reader. The golden contacts are at the front on the
right.
Once the card has been inserted into the reader, you can select
the relevant update function within the program. The data is
then transmitted to the system.
- From starting screen click Service programs
word "nussbaum"), After-Sales-Service
screen Diagnostics) and click Smart Card Data
left half of the screen you get all information about your main
smart card. On the right half all information about the secondary
smart card (if it is entered in the smart card reader)
- when you got the information about the secondary smart card
on the screen click
information from secondary will be copied to main smart card.
1300 0186
(you are now in
to upgrade the main smart card. All
(pass-
. On the
83