Signal: mandatory insertion of an electrical protection
(fig.I/10)
Connect to a circuit protected by fuses or HACR type circuit
breaker.
EN
Signal: obligation to disconnect the machine before
carrying out maintenance / repairs (fig.I/11)
Disconnect the power supply before servicing the machine.
Do not replace fuses or other electrical components with an
electrically powered machine. Use only original spare parts.
Signal: ground connection (fig.I/12)
This equipment must be properly grounded! Failure to do so
can result in severe personal injury from electrical shock!
Signal: Rohs2 compliant machine (fig.I/13)
Signal: RAEE compliant machine (fig.I/14)
For decommissioning, comply with the standards in force in
the country where it is used.
Signal: Contains flammable gas, specific refrigerant gas (fig.I/15)
Follow the instructions given in chap. II/4.3 of this manual. Use only the gas
indicated on the label.
G5 G10
FRIGOMAT
fig.I10
fig.I/11
fig.I/12
fig.I/13
fig.I/14
fig.I/15
M04.37562 R.2021.10.23
5
SAFETY DEVICES
The machine is equipped with the following safety devices:
Shearing-prevention safety device
Implemented by means of a safety circuit compliant with the European
directive, it intervenes when the cover is opened, temporarily switching the
machine to STOP mode.
Beater motor overheating safety device
Implemented by means of automatic reset circuit breaker-relays; they
protect the machine beater motor operation from overloads.
Hermetic compressor motor overheating safety device
Implemented by means of automatic reset thermal-ammetric sensors; they
protect the machine compressor motor operation from overloads. The
protection device intervention determines the temporary stop of the
compressor motor only.
Protection against short circuit of auxiliary utilities:
Implemented by fuses which intervene on the auxiliary power supply in the
event of short-circuits.
Safety circuit SELV
The keyboards are powered by low voltage safety