VI APPENDICE / APPENDIX / SUPPLEMENT / 6tttttttt / ssikisis / sisisisi / ssjjsjsjsj
V PROGRAMMING
These operations are reserved exclusively for authorised from
the manifacturer and qualified personnel.
1
RESET
Carry out the Reset procedure when replacing an electronic board, to solve
any faults due to microprocessor blocking or when you want to recharge the
manufacturer's factory data, resetting any calibration.
To reset the electronic board, refer to the following instructions:
Power the machine.
With the machine at STOP,
press the STOP and
AGITATION/P keys
simultaneously and release
them only after the
password identification
screen appears (fig.V/01).
Press the "STOP (▲)" "AGITATION (▼)"
and "PRODUCTION (◄►)" keys to enter
the password and then confirm it (fig.V/05).
If you do not know the password, contact the
Frigomat assistance service.
Once the password has been recognized, the software version installed on
the electronic card is
displayed.
Press the PRODUCTION/
OK and AGITATION/P keys
at the same time and
release only after the PRG
message appears on the
display (fig.V/03).
Press the STOP key to exit the Reset procedure.
G5 G10
FRIGOMAT
fig.V/01
fig.V/02
fig.V/03
M04.37562 R.2021.10.23
2
PROGRAMMING
For programming the electronic board, refer to the following instructions:
Make sure that the covers are assembled in the machine and in the closed
position.
Power the machine.
With the machine at STOP,
press the STOP and
AGITATION/P keys
simultaneously and release
them only after the
password identification
screen appears (fig.V/04).
Press the "STOP (▲)" "AGITATION (▼)"
and "PRODUCTION (◄►)" keys to enter
the password and then confirm it (fig.V/05).
If you do not know the password, contact
the Frigomat assistance service.
When the password has been accepted, the
screen accesses the list of programming
steps directly. The first programming step
P01 is selected automatically.
If you do not wish to change the value of the
selected step, press "STOP (▲)" to directly
access the following step (fig.V/06).
If, instead, you wish to change the
selected step, press
"PRODUCTION (◄►)" to access
the parameters relative to the same
step, and subsequently press
"STOP(▲)" or "AGITATION (▼)" to
increase or decrease the value
(fig.4). Subsequently, press the
"PRODUCTION (◄►)" key to
confirm the data. (fig.V/07)
To quit the programming and save your
changes, press the key "STOP (▲)" to see
a list of steps to the end. The exit from the
programming is automatically.
The list of parameters and related programming specifications is shown in
TAB V/01 at the end of this section.
14
for the technician
EN
fig.V/04
fig.V/05
fig.V/06
fig.V/07
fig.V/08