FAILURES IDENTIFICATION
4.1 Management of alarms
MESSAGE
DESCRIPTION
EME
Cover open or unassembled.
TER
A motor circuit breaker has intervened or the transformer fuse
breakdown.
Batch freezing time-out alarm.
End
TEv Int
The cylinder probe is interrupted or in short-circuit.
TEv cor
TEc Int
The suction probe is interrupted or in short-circuit.
TEc cor
T-S
Reached the minimum temperature allowed on suction probe.
PUR
Report the possible absence of power supply during the phases of
preserving mode
1
= These operations are reserved exclusively for authorised from the manifacturer and qualified personnel.The list of authorized technical assistance
centers is available on the site: www.frigomat.com/en/partners/world.
The manufacturer declines all and any liability for damage caused by failure to comply with the above indications.
G5 G10
FRIGOMAT
M04.37562 R.2021.10.23
SOLUTION
Verify that the cover is assembled and in the closed position.
Wait a few minutes and then press STOP to restore machine
operation. If the alarm continues, contact the technician
In the production cycle, select lower consistency levels. Make sure
that the product is balanced correctly. If the alarm continues, contact
1
the technician
.
Contact the technician to check and replace the faulty probe.
Contact the technician to check and replace the faulty probe
Make sure the freezing cylinder is not empty, that the mixture is
properly balanced and that the selected program is suitable for the
product being processed. If the alarm persists, call the technician.1
Check the reasons for the absence of power supply and the state of
of preservation of the product.