"Hint 16"
"Wrong AWP SerNum"
"Hint 17"
"High Vert Stress"
"Error 101"
"EEPROM not valid"
"Error 102"
"QPower linkdown"
"Error 103"
"QIntface linkdwn"
"Error 104"
"AWP linkdwn"
"Error 201"
"LowerBB Motion"
"Error 202"
"LowBB WrongDir"
"Error 203"
"UpperBB Motion"
110
"Hint 16"
"Laser ID
falsch!"
"Hint 17"
"Zu hohe
Last!"
"Error"
"Error 101"
"Sw.
ungueltig!"
"Error 102"
"QPower linkdown"
"Error 103"
"QIntface linkdwn"
"Error 104"
"AWP linkdwn"
"Error 201"
"LowerBB Motion"
"Error 202"
"LowBB WrongDir"
"Error 203"
"UpperBB Motion"
Trouble shooting
"Hint 16"
"AWP Laser Sensor Serial Number not valid"
Call the Technical Assistance Service
"Hint 17"
"Excessive bead extraction force"
The message appears after the fi fth consecutive interruption.
The blocked tool must be rearmed with the lever. Check the
conditions of the tyre and press the MANUAL MODE key
to continue.
A list of the ERRORS shown on the Display:
"Error 101"
"The Eprom data is not valid"
This error may be displayed only at machine start up if
the software detects an error in the saved data or if the
data is absent; (Call the Technical Assistance Service).
"Error 102"
"Communication with motor control failed"
There is a communication failure with the Motor Control
Card; (Call the Technical Assistance Service).
"Error 103"
"Communication with solenoid valve control
failed"
There is a communication failure with the Solenoid
Valve Interface Card; (Call the Technical Assistance
Service).
"Error 104"
"Communication with AWP failed"
There is a communication failure with the Laser
scanner; (Call the Technical Assistance Service).
"Error 201"
"Lower Bead Breaker Operation"
In automatic procedures, this error may be displayed
when the lower bead breaker starts but does not
move, or does not move smoothly; (Call the Technical
Assistance Service).
"Error 202"
"Lower Bead Breaker Wrong Direction"
This error may be displayed when the lower bead
breaker is activated but moves in the opposite direction
to the required one; (Call the Technical Assistance
Service).
"Error 203"
"Upper Bead Breaker Operation"
In automatic procedures, this error may be displayed
when the upper bead breaker starts but does not
move, or does not move smoothly; (Call the Technical
Assistance Service).
Operator's Manual
.