- Change the filters at the intervals laid down, using only filters recommended by the
manufacturer.
- Only use the oils recommended by the manufacturer.
- Never confuse the vacuum pump oil with the oil for the air-conditioning systems.
Failure to comply with any of these safety rules leads to any form of guarantee for the machine
being rendered null and void.
Machine is provided with class III safety valve, in case of malfunctioning it can create an
external sack of flammable gas; keep the machine in well ventilated area.
WARNING: R134a/R456a and/or R1234yf vapor/gas refrigerant are heavier than air and may
thicken on the floor or inside the cavity/pits and cause choking by reducing oxygen available for
breathing.
At high temperatures the refrigerant decomposes releasing toxic and caustic substances,
hazardous for the operator and the environment. Avoid inhalation of the refrigerants and A/C
system oils .
Exposure can irritate the eyes and airways.
WARNING! The machine must be connected to a socket with effective ground
WARNING: This is a class "A" product. In a domestic environment this product may
cause radio interference. In such cases, the user may be required to take adequate
measures.
Never leave the device unsupervised or unattended during use, use it only for the
purposes described here, improper use will invalidate the warranty
Typical WLAN transmit power:
-FREQUENCY BAND: 2400-2500 MHz
-MAXIMUM RADIO-FREQUENCY POWER: +20,0 dBm
LEAK STOP
-
Recovery/recycling equipment must be used with refrigerants authorized by the
manufacturer.
-
The authorized refrigerants are listed in the user manual or are available through
technical assistance.
-
The manufacturer prohibits the use of recovery/recycling equipment on A/C systems
containing chemical and other leak sealants.
-
The use of unauthorized refrigerants or sealants will invalidate the warranty.
REFRIGERANT AND LUBRICANT - PERSONAL
PROTECTIVE EQUIPMENT AND PRECAUTIONS
Handled with caution refrigerants and pressure vessels, since otherwise there could be health
risks .
The operator must wear safety glasses, gloves and suitable clothing to work , contact with
refrigerant may cause blindness (eyes), and other physical damage (frostbite) to the operator.
Avoid contact with the skin, the low boiling temperature (about -26°C for R134a/R456a and
about -30°C for R1234yf ) can cause cold burns.
Do not change the setting of the relevant devices for safety, do not remove the seals of the
safety valves and control systems . Do not use external tanks or other storage containers that
are not approved, or without safety valves.
During the functioning, the air vents and
ventilation equipment must not be blocked or
covered