ALARMS
HIGH PRESSURE ALARM: Software advise when the pressure of the fluid in the circuit is too
high (20bar). The recovery operation is automatically interrupted.
FULL BOTTLE ALARM: Software advise when the bottle is filled to more than 80% of
maximum capacity; that is, 10 kg. The RECOVERY operation is automatically interrupted (to
cancel this alarm, charge one or more A/C systems before recovering any more refrigerant).
EMPTY BOTTLE ALARM: Software advise when the quantity of refrigerant fluid contained in
the bottle is low.
SERVICE ALARM: Software advise whenever the total recovered refrigerant amounts to 100
kg. To deactivate the alarm, replace the filters and the vacuum pump oil. A code for canceling
the alarm is supplied with the spare filters.
AIR PURGE ALARM: Software advise when there is air inside the bottle when the machine is
switched on. To deactivate the alarm, purge the air from the bottle.
INSUFFICIENT GAS ALARM: Software advise when the charging quantity set exceeds the
difference between availability and bottle minimum.
FAN STOPPED ALARM: This is displayed and a software advise sounds when the extraction
fan is not moving.
VACUUM PUMP OIL CHANGE: Software advise after 20 hours of work of the vacuum pump;
change the oil of the vacuum pump