FILLING TYPE
From the SETUP, select FILLING TYPE:
Select Vapor Compensation or C.A.R. Filling to change filling type. The machine will return to
the SETUP MENU.
METHOD 1: VAPOR COMPENSATION
Standard filling procedure described in AUTOMATIC and MANUAL PROCEDURE
METHOD 2: C.A.R. FILLING
This is the new method used in new range of products. It is a very accurate way of charge a
vehicle, it has granted accuracy better than 1% with new Products.
At the end of the filling the user will be asked to execute the following procedure:
Disconnect HP coupling. Start A/C system with LP coupling connected, press ENTER
The A/C system will recover the refrigerant into the service hoses, then the following screen will
be displayed:
Disconnect LP coupling from A/C system, then press ENTER to continue:
INSTRUCTIONS MANUAL
FILLING TIMPE
C.A.R. FILLING
VAPOR COMPENSATION
Disconnect HP coupling Start A/C system with LP
coupling connected end press ENTER
Disconnect LP coupling from A/C system end press ENTER
-56-
DD/MM/YY XX:XX PM
ESC
DD/MM/YY XX:XX PM
ENTER
DD/MM/YY XX:XX PM
ENTER