START PROCEDURE
NOTE: the STOP button literally pause the running procedure. In the final phase of the charge
the procedure hasn't to be paused or stopped to avoid to compromise the precision of the
procedure. After selected all the procedure data, press ENTER to continue, the following
screen will be displayed:
Connect and open the HP and LP coupling to the A/C system, then press ENTER, the
machine will charge the quantity of gas set
Then the following screen will be displayed.
Disconnect HP coupling. Start A/C system with LP coupling connected, press ENTER
The A/C system will recover the refrigerant into the service hoses, then the following screen will
be displayed:
INSTRUCTIONS MANUAL
CHARGE
Connect and open HP and LP couplings
to A/C system and press ENTER
CHARGE
Gas charged:
Tank Pressure
A/C pressure
Tank Temperature
Disconnect HP coupling Start A/C system with LP
coupling connected end press ENTER
Disconnect LP coupling from A/C system end press ENTER
-48-
DD/MM/YY XX:XX PM
ESC
ENTER
DD/MM/YY XX:XX PM
86g / 100 g
6.6 bar
STOP
2.9 bar
25.5 °C
DD/MM/YY XX:XX PM
ENTER
DD/MM/YY XX:XX PM
ENTER