INSTRUCTIONS MANUAL
R134a/R456a TANK CELL
1
Disconnect the machine from the electrical supply.
Procure a known reference weight from 20 kg.
Remove
the rear plastic (ref 1, Fig.50) cover to
access the machine bottles.
Unscrew the R134a/R456a bottle lock nuts (ref 3b,
FIG. 50
Fig.51).
Separate the heating coil (ref 2b, Fig.51) from the
tank (do not touch or disconnect the wires of the resistance coil).
1b
1a
2b
2a
3b
3a
FIG. 51