During the recovery phase, the machine displays the quantity of refrigerant recovered, in
grams.
Upon completion of recovery, the machine
displaying the used oil extracted from the A/C system during the recovery phase. The oil
discharge operation lasts 4 minutes
Unscrew and disconnect HP and LP coupling from A/C system end press ENTER.
You are asked to enter the vehicle's PLATE, the FRAME NUMBER, the KM/Miles and the
Operator Code. Press ENTER.
INSTRUCTIONS MANUAL
RECOVERY/RECYCLE
Gas recovered:
A/C pressure
Tank Temperature
RECOVERY/RECYCLE
Gas recovered:
A/C pressure
Oil recovered:
Tank Temperature
will stop and discharge, while automatically
Close and disconnect HP and LP couplings
from A/C system and press ENTER
Plate:
-
VIN:
-
Miles:
-
Operator code:
123456
-37-
DD/MM/YY XX:XX PM
0g
-0.5 bar
25.2 °C
STOP
DD/MM/YY XX:XX PM
0g
STOP
0.0 bar
0 ml
25.2 °C
DD/MM/YY XX:XX PM
ENTER
DD/MM/YY XX:XX PM
ENTER