26
100
5-77
5-78
5-62
5-79
Operation
Message E9
Message E9 means that at least one error has occurred
during the optimisation cycle (System messages
7.1).
— Press BALANCING or ESC key to quit the
optimisation program and, if desired, start a new
optimisation.
Figure 5-77 MINIMISATION "Un.12"
— Clamp the wheel.
— Position the valve so that it is exactly perpendicular
to and above the chuck.
— Confi rm the valve position by pressing menu key
26.
The MINIMISATION "Un.13" screen is displayed(Fig.
5-78).
Figure 5-78 MINIMISATION "Un.13"
START is displayed on the screen
— Perform the wheel measuring run.
A measuring run is performed.
The BALANCING screen appears (Fig. 5-62).
Finish weight Minimisation
Figure 5-62 BALANCING
— Balance the wheel according to the readings.
If the silent wheel running conditions cannot be
improved on, the following message is displayed:
Fig. 5-79
H0
Silent wheel running conditions cannot be
improved by optimisation.
F