User Code
Code C0
Setting the factory-adjusted modes of operation
F
(
5.2.2).
0* =
No action
1 =
Set the default values
(status 1 is displayed for a short time)
After the confi rmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C1
Selecting the defi nition of the imbalance value in steps
Selecting the resolution of
from 0.05 or 0.25 oz. (respectively 1 or 5 grams).
1 or 5 g, or 0.05 or 0.25 oz increments
0*
=
0,25 oz (5 grams) defi nition
0* =
5 g (0.25 oz) increments
1 =
1 g (0.05 oz) increments
1
=
0,05 oz (1 gram) defi nition
After the confi rmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C2
Selecting suppression of minor unbalance
readings
0 =
Suppression off
1* =
Suppression on
After the confi rmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C3
Selection of unbalance indication, in grammes or
ounces, active when the machine is switched on
1* =
Readings in ounces
0* =
Readings in grammes
0 =
Readings in grammes
1 =
Readings in ounces
After the confi rmation OK, this operating mode can be
acquired in the permanent memory (C10).
* = Factory-adjusted mode