A
132
7-3
26
27
User Code
2 = Positioning brake after measuring run for right
plane.
Note: The selection is permanently acquired.
Code C12
Measuring runs counter
Example: 220,219 measuring runs so far performed
(Fig. 7-3).
The following counters can be displayed:
1 = Total number of measuring runs
2 = Total number of measuring runs where balance
result was considered OK
3 = Number of optimisations or minimisations
4 = Number of measuring runs in service mode
5 = Number of measuring runs since the last
calibration
6 = --
Every measuring run actually completed is stored.
Maximum count is 999,999 runs. Once this number is
reached, the counter is reset to zero. The information
is primarily useful for statistical purposes, e.g. to obtain
evidence of load intervals of parts when defective, or of
monthly (yearly) use of the machine, etc. The measuring
runs performed while the machine is on are transferred
into the permanent memory and added when it is
switched off. The counter cannot be reset.
The number indicating the List item (from 1 to 6) is
temporarily displayed on the left (A, Fig. 7-3)
Code C13
Starting the measuring run by closing the wheel
guard
0 = Start via START key
1* = Start via wheel guard
The selected mode of operation can be acquired in the
permanent memory (C10).
Code C14
Recalibration of the machine by the operator
F
6-2. Recalibration by the user.
* = Factory-adjusted mode