70
A
5-27
5-28
5-29
Operation
5.9.1.2 Application with gauge arm
Weight will be positioned to the left compared to
the contact point (A) of Gauge on rim (Figure
5-27).
Refer to (Figure 5-28).
The gauge arm must be used to apply the stick-on
weights.
• Turn the wheel until it reaches the balancing
position of the right plane.
• Press break pedal to lock the wheel in this
position.
Decide now whether to use the Split Weight Mode
F
SWM (
5.10).
• Clean the fi tting position before attaching the
stick-on weights.
• Insert at the centre of the arm gauge a stick-on
weight that complies with the unbalance detected
and remove the adhesive protective strip (Figure
5-29).
Note: When the measuring arm has been
removed and the correct position has been
reached, the unit emits an acoustic signal.
• Apply the weight to the correct point of the rim.
• Rotate the wheel to the next WAP position, put
the stick-on weight on the arm and apply the
weight at the left plane reference point.
• At the end perform a measuring run.