130
Troubleshooting
H90
Wheel acceleration was too slow, or braking was too
weak after a measuring run. If the main shaft does
not reach the required rpm, check whether the brake
was activated or whether the mass of the wheel is too
great. In this case:
Release the brake.
Make sure that the shaft with the wheel clamped on it
can rotate freely.
Turn the wheel by hand then press the START key.
If the error cannot be eliminated, call the service team.
H91
Rpm variations during measuring run. The brake may
be engaged.
Release the brake.
Make sure that the shaft with the wheel clamped on it
can rotate freely.
Repeat the measuring run.
H946
Incorrect selection of Lifter Version.
Call service team.
7.2
After-sales service
7.2
Customer technical assistance
Contact your area agent.
The company website provides information about the
Customer Assistance service around the world:
Contact your area agent.
http://www.johnbean.com
The company website provides information about the
http://www.johnbean.ca
Customer Assistance service around the world:
Customer Care
http://sbs.snapon.com/support
Phone: 800-362-4618
Hotline (International) +49 8634 622-8996
or: 800-362-4608·
http://www.snapon-equipment.eu
Hotline (German): +49 8634 622-8994
Reception +49 8634 622-0
· Snap-on Equipment Germany ·
· Konrad-Zuse-Straße,1 D-84579 Unterneukirchen ·