Tabla de contenido

Publicidad

64
5-19
5-21
Operation

5.6.3 Automatic Mode

5.6.3.1 Distance and Diameter Automatic Entry
with measuring arm
• Make sure that the measuring arm is in rest position.
• Correctly position the measuring arm on rim, so that
its reference point touches the rim reference point,
as shown by the arrow (Fig. 5-19). Keep arm in
measuring position until a short beep is heard to
indicate that the value has been acquired.
WARNING:
With laser pointer enabled, arm gauge must be
positioned on the left compared to the desired weight
position (Fig. 5-21).
Laser pointer can be disabled and only the measuring
arm can be used; (F5.9.1.2).
Note: a result recalculation can be performed by the
machine only after the run.
Select weight application positions by pressing on the
screen:
-
Selected position (yellow)
-
Available position (grey)
To shift to a different balancing Mode.
If more than one wheel of the same type needs to be
balanced (with the same nominal dimensions) the data
need only be set for the fi rst wheel. The selections
stay set until other new data are set or the machine
is switched off.
The alternative combinations vary based on the
starting measuring positions. The unbalance values
will automatically adapt to the new selections.

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

B340lEewb331a

Tabla de contenido