Kärcher MIC 50 Manual Del Usuario página 76

Ocultar thumbs Ver también para MIC 50:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 212
Expansion reservoir for coolant
5
1. Remove the left-hand side cover12.7.3 Side covers.
2. Check the filling level in the expansion reservoir.
Note
The coolant level must be between the upper (MAX) and lower
(MIN) mark.
3. Top up fresh coolant if necessary.
4. Also check the filling level in the radiator, see chapter .
5. If the expansion reservoir is totally empty, top up the radiator
first.
12.7.14Topping up the coolant in the radiator
WARNING
Risk of injury due to pressurised cooling water
Do not unscrew the radiator cap until the cooling system has
cooled down and is no longer under pressure.
CAUTION
Risk of burns due to hot components
Do not touch any parts of the cooling system when the engine is
hot. Open the cooling system only when the engine is cold.
ATTENTION
Material damage due to incorrect coolant
Top up the coolant only when the engine is cold.
Use the water frost protection mixture.
Do not mix the antifreeze.
Only use soft or distilled water.
For the coolant, see chapter .
Radiator cap cover
1
Radiator cap
2
1. Tilt up the radiator cap cover.
2. Turn the radiator cap one click to drain pressure from the radi-
ator.
3. Unscrew the radiator cap when the radiator has depressur-
ised.
4. Slowly fill the radiator bubble-free up to the outlet for the cool-
ant expansion reservoir.
5. Screw the radiator cap on tight.
6. Refill the coolant expansion reservoir. See chapter 12.7.13
Checking the coolant level and topping up the coolant.
76
12.7.15Cleaning and replacing the air filter MIC 50
Lock
1
Air filter housing
2
Filter cartridge
3
Safety cartridge
4
1. Remove the right-hand side cladding.
2. Open the lock on the air filter housing.
3. Turn the air filter housing anticlockwise and remove it.
4. Pull out the filter cartridge and safety cartridge.
5. Clean the air filter housing on the inside.
6. Knock the dust out of the filter cartridge on a hard surface.
Do not blow out the filter cartridge with compressed air.
7. Check that the filter cartridge and sealing surfaces are clean
and undamaged.
Renew a heavily soiled or damaged filter cartridge.
8. Renew the safety cartridge.
Do not re-use a used safety cartridge.
9. Insert the cleaned filter cartridge.
10.Fit the air filter housing and turn it clockwise as far as it will go.
11.Close the lock on the air filter housing.
12.Attach the right-hand side cladding.
12.7.16Cleaning and replacing the air filter MIC 70
Wing screw
1
Air filter housing
2
Lock (3x)
3
Filter cartridge
4
Safety cartridge
5
1. Remove the right-hand side cover.
2. Undo the wing screw, do not unscrew.
3. Pivot the complete air filter unit outwards as far as it will go.
4. Tighten the wing screw.
5. Open the locks on the air filter housing.
6. Remove the air filter housing.
7. Pull out the filter cartridge and safety cartridge.
8. Clean the air filter housing on the inside.