Operating
Display
Explanation
Mains phases
Number of phases in
the supply cable.
Cable type
Type of vehicle charg-
ing cable. The cable
type provides important
information for setting
the maximum charging
current.
Restricted operation
This figure indicates
which charging power
sensors are restricted
due to overheating:
0: Microcontroller
overtemperature
1: Relay overtem-
perature
2: Internal over-
temperature
3: Infrastructure
cable sensor 1
overtemperature
4: Infrastructure
cable sensor 2
overtemperature
78
Ground monitoring
Electric shock, short cir-
DANGER
cuit, fire, explosion
Use of the charger without active ground monitoring
can cause electric shocks, short circuits, fire, explo-
sions or burns.
e
The charger should preferably be operated in
earthed mains supply systems.
e
Only deactivate ground monitoring in non-
earthed mains supply systems.
e
Activate ground monitoring in earthed mains
supply systems.
To activate and deactivate ground monitoring g Refer
to chapter "Activating and deactivating ground moni-
toring" on page 72.
Adapting the charging current
If the charging current to the vehicle is too high, this
may trip the fuse, leading to a power failure in the
area covered by that fuse.
If an energy manager is connected to the charger, the
overload protection monitors the charging current to
the charger. If no energy manager is available in the
home network, you must define a maximum current
for the charger.
The charging current you enter must not exceed the
maximum charging current that the electrical instal-
lation can cope with.
Pay attention to the following when determining the
maximum charging current:
Type of cable connected to the charger
Other loads connected to this cable or fuse
Information about supply cables and their use in dif-
ferent countries Refer to chapter "Selecting a Supply
Cable" on page 61..
Information
The charging power must never be set higher than
the maximum available power of the electric circuit.
If you are unsure about this, consult a qualified elec-
trician.
Information
If an energy manager is connected, its settings will
overwrite the value you enter.
b The vehicle cable is connected to the charger.
e
In the Web Application, use the controller to set
a minimum and maximum charging current.
Service
View device information
This information is based on the charger data, e.g. the
version number, serial number and host name.
Your Porsche service partner will need this data in
the event of an error message.
View the total lapsed time information
Display
Explanation
Total energy consump-
Shows this charger's
tion
total energy consump-
tion for all previous
charging processes.
Total charging time
Shows this charger's
total charging time for
all previous charging
processes.