III.1 Technical Data
EQPI3X
AUTOMATIC 1 (A1) cooling mode
Nominal cooling capacity
EER
Nominal thermal potential DS
Nominal cooling capacity EN 14511
EER EN 14511
SEER EN 14825
AUTOMATIC 2 (A2) cooling with heat recovery mode
Nominal cooling capacity to the main exchanger
Nominal thermal capacity to the secondary exchanger
TER
Nominal cooling capacity to the main exchanger EN 14511
Nominal thermal capacity to the secondary exchanger EN 14511
TER EN 14511
SELECT 1 (S1) / SELECT 2 (S2) / AUTOMATIC 3 (A3) heat pump mode
Nominal heating capacity
COP
Nominal thermal potential EN 14511
COP EN 14511
SCOP EN 14825
Sound pressure
Sound power
Sound power with FNR accessory
Scroll/step compressor
Circuits
Fans
Fan nominal air flow rate
Main heat exchanger nominal flow rate/pressure drop
Residual head on the main heat exchanger (P1/P2)
Residual head on the main heat exchanger (ASP1/ASP2)
Main heat exchanger nominal flow rate/pressure drop (S1)
Main and secondary/recovery heat exchanger water content
Nominal flow rate/pressure drop DS
Tank water content (ASP1/ASP2 installation)
Amount of R410A refrigerant
Polyester oil charge
Electrical data
Absorbed power in AUTOMATIC 1
Absorbed power in AUTOMATIC 2
Absorbed power in AUTOMATIC 3 / SELECT 2 / SELECT 1
Pump absorbed power (P1/ASP1)
Pump absorbed power (P2/ASP2)
Electrical power supply
Auxiliary power supply
Nominal current
Maximum current
Starting current
Starting current with SFS
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Height
Width
Length
Main and secondary/recovery heat exchanger water connections
DS water fittings
Weight
EQPI3X
EQPI3X
270
(*)
kW
66,7
(*)
3,03
(±)
kW
-
(*) (°)
kW
66,6
(*) (°)
3,00
(**)
kW
68,6
(**)
kW
88,2
(**)
7,76
(**) (°)
kW
68,5
(**) (°)
kW
88,4
(**) (°)
7,53
(***)
kW
72,7
(***)
3,37
(***) (°)
72,8
(***) (°)
3,33
3,96
(****)
dB(A)
52
(*****)
dB(A)
84
(*****)
dB(A)
77
2
n°xKw
6x0,125
8x0,125
m
3
/h
20.200
25.650
(*)
m
3
/h / kPa
11,5/25
13,6/30
(*)
kPa
158/217
142/213
(*)
kPa
151/211
133/204
(***)
m
3
/h / kPa
12,5/30
14,6/35
l
7,1
(±)
m
3
/h / kPa
-
l
230
Kg
24
Kg
6,6
270
(*) (■)
kW
22
(**) (■)
kW
20,2
(***) (■)
kW
21,6
kW
1,1
kW
2,2
V-ph-Hz
V-ph-Hz
(*) (■)
A
35
(■)
A
59
(■)
A
137
(■)
A
98
A
2,4/4,5
2,4/4,5
270
mm
1540
mm
1210
mm
3250
Ø
2" VIC
Ø
-
270
kg
1060
280
290
2100
79
86,4
93,2
112,5
3
3
2,89
-
-
-
78,8
86,2
93
112,3
2,97
2,97
2,86
84,5
87,2
96,3
115,1
108,7
112,1
124
148,1
7,73
7,75
7,7
84,3
87,0
96,1
114,9
109,1
112,4
124,3
148,4
7,43
7,52
7,47
84,9
92
100
120,1
3,36
3,38
3,36
85,1
92,2
100,2
120,3
3,32
3,35
3,33
4,02
4,02
3,99
53
53
53
85
85
85
77,5
77,5
77,5
1+i / continuous regulation (20÷100%)
2
2
2
8x0,125
8x0,125
6x0,69
25.650
25.650
53.950
14,9/28
16/25
19,4/28
111/188
114/191
110/189
99/176
102/179
104/184
15,8/32
17,2/29
20,7/32
8,8
10,1
10,1
-
-
-
6,4/13
230
230
230
24
24
24
6,9
7,2
7,2
280
290
2100
26,3
28,8
32,3
25,0
25,7
28,6
25,3
27,2
29,8
1,1
1,5
1,5
2,2
2,2
2,2
400-3+N-50
230-1+N-50
41,8
45,8
51,3
75
81
81
199
249
249
140
170
170
3,2/4,5
3,2/4,5
3,2/6,3
280
290
2100
1540
1540
1540
1210
1210
1210
1520
3250
3250
3250
3450
2" VIC
2" VIC
2" VIC
2" 1/2 VIC
-
-
-
1" 1/4 VIC
280
290
2100
1085
1095
1105
2115
2130
126,2
3
3,03
37
43
125,9
2,97
2,99
128,4
164,3
7,74
7,91
128,1
164,6
7,49
7,62
132,9
3,35
3,28
133,2
3,32
3,24
4,01
3,91
56
56
88
88
82
82
2
2
6x0,69
53.950
21,7/35
99/181
92/174
22,9/39
11,4
11,4
7,4/16
440
440
26
29
10,3
10,3
2115
2130
37,5
41,6
34,0
37,0
35,8
40,5
1,5
1,5
3
3
59,6
66,1
81
91
257
305
171
201
3,2/6,3
2115
2130
2000
2000
1520
3450
2" 1/2 VIC
1" 1/4 VIC
2115
2130
1435
1455
153

Publicidad