5. Ensure that the electrode does not project into the toothed
space of the rotor. If necessary, shorten the electrode.
6. Switch on the welding power supply.
7. Press the END. 0POS button in order to bring the rotor
to the home position (0-position).
8.5
Clamping the workpieces
1. Open both swivel clamps.
2. Insert Workpiece 1 and Workpiece 2.
The electrode has to be positioned centrally over the
workpiece joint.
3. Fix Workpiece 1 and Workpiece 2 (4) by closing the swivel
clamps (3).
4. Close the latches (1) to tension the swivel clamps.
5. If necessary, carry out a tolerance compensation by using
the adjusting screw (2).
[REV. 20230213] OW_ORBIWELD_BA_821060201_00__INH_EN
Set-up and assembly
1
2
3
4
Orbitalum Tools GmbH D-78224 Singen www.orbitalum.com