Descargar Imprimir esta página

Numatic TVL850/150 Traducción Del Manual De Uso Original página 65

Publicidad

!
ALWAYS ENSURE THAT THE MACHINE IS
SWITCHED OFF PRIOR TO ANY MAINTENANCE.
After use, empty waste water tank using emptying hose and flush out with
A
clean water.
Remove floor tool vacuum hose ensuring you remove the U-bend clip and flush
B
out with clean water.
C
Empty clean water tank, using emptying hose and flush out with clean water.
Remove hoses
Hold the handles and lift the seperator
away from the machine
Hold the handles and lift the seperator
away from the machine
!
IMPORTANT: IF THE DEBRIS BASKET IS ALLOWED TO BECOME CLOGGED,
Press in the 2 retaining handles of the
seperator
Clean and examine rubber seal during
each clean
Clean and examine rubber seal during
each clean
VACUUM PERFORMANCE CAN DETERIORATE.
65
Machine Cleaning
GB
!
Remove and clean vacuum shut off filter
Located in your waste water top tank is
a vacuum shut off system, this prevents
suction when the waste water tank is full.
It also prevents foam created by high-
foaming detergents from entering the
motor.
Sometimes the float vents get clogged
and blocked, clean to ensure correct
operation. Remove debris basket filter and
rinse using clean water, and refit. Refit
both of the vacuum hoses.
A
B
C
!

Publicidad

loading

Este manual también es adecuado para: