Once the packing material has been removed, check the machine visually for any signs of damage.
Keep the packing materials out of the reach of children as they can be a source of danger.
N.B.: Keep the packing for possible future transport.
Maximum machine space requirements are 2220 x 2000 mm with a minimum distance
from walls as shown in the diagram B/4.
CAUTION! These measurements are also the tyre changers
working range.
Persons other than specially trained and authorized
operators are expressly forbidden to enter this area.
Position the tyre changer lifting it with the specific bracket (1, Fig. A) with the
tool carrier arm (2, Fig. A) lowered all the way, the spindle (3, Fig. A) closed and
the tool carrier slide (4, Fig. A) at its stop close to the arm.
It is not essential to anchor the machine to the floor.
However, the floor must be smooth and permit the platform rollers to move
freely.
6.4 ELECTRIC HOOK UP
Before making any electric hook up, check to be certain that the mains voltage
corresponds to that stamped on the voltage tag (attached to the cord near the
tyre changer's plug).
It is absolutely essential that :
- the system is equipped with a good grounding circuit.
- The machine is connected to a power supply line circuit breaker set for 30
mA.
- The power socket take is adeguately protected against overcurrents with fuses
or circuit-breakers with rated values as shown in the table below.
Note the required power draw as highlighted on the data plate fixed to the tyre
changer.
Check to make sure the shop electric wiring circuit is dimensioned sufficiently to
carry this.
POWER SUPPLY
230V - 3Ph - 50/60Hz
400V - 3Ph - 50/60Hz
TTC 600
6.2 UNPACKING
6.3 WORKPLACE REQUIREMENTS
RATED CURRENT
FUSE
SWITCH
25A AM
25A
16A AM
16A
600 mm
4
3
32
(1*/,6+ ,QVWUXFWLRQV PDQXDO
2500 mm
B/4
2
1
A
6
B/6