Fault Clearance; Maintenance Of The Parking Heater; Circuit Diagram Park Heating (E 39) M52 - BMW 5 Serie Manual De Instrucciones

Tabla de contenido

Publicidad

19. Fault clearance

If the above measures do not lead to a remedying
of the fault, fault clearance should be undertaken as
described in the following. The blade terminal fuse
described in the chapter is located in the E-box.
F 39 64 243 R
Take 20 A blade terminal fuse out of the blade
terminal fuse holder. After waiting for at least 10
seconds, put blade terminal fuse in again.
F 39 64 244 R
After waiting for at least 10 seconds put parking
heater into operation with timer or Telestart hand
transmitter.
F 39 64 245 R
After waiting for 3 - 10 seconds, take 20 A blade
terminal fuse out of the blade terminal fuse holder.
F 39 64 246 R
After waiting for at least 30 seconds switch off
parking heater with timer or Telestart hand
transmitter.
F 39 64 247 R
Insert 20 A blade terminal fuse in blade terminal
fuse holder again.
F 39 64 244 R
After waiting for at least 10 seconds put parking
heater into operation with timer or Telestart hand
transmitter.
20. Maintenance of the heater
The parking heater should be checked by a BMW
service centre at regular intervals or at the latest
at the beginning of the period when the parking
heater will normally be in use.
Note the operating instructions in the
instruction manual.
To avoid starting problems as a result of operating
the park heating, we recommend that the vehicle
is driven daily for 15 - 20 km so that the vehicle
battery gets sufficiently recharged.
Subject to technical modification.
21. Circuit diagram park heating
(E 39) M52
F 39 64 249 R
Key
A
Fuse holder in the E-box
A11
Control unit heating or heating/air
conditioning
A12
Time switch*
A14
Parking heater with control unit and
Telestart receiver
F1
Branch cable blower control
F2
Branch cable blower control
G1
Branch cable voltage supply
parking heater
G2
Branch cable control system
parking heater
K1
Blower relay
X166
Ground terminal 31
X610
Connector blue, 26-contact,
at control unit A11
X18326 Positive supply terminal 30 in the E-box
Y7
Metering pump
*
optional
29

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

E 39M 52

Tabla de contenido