Battery Charger Fault Finding; Ec Declaration Of Conformity - SDMO RES 9.5EC Manual De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

5.5. Battery charger fault finding

Use the battery charger LEDs and the table in figure 5.4 to perform fault finding on battery charger operating faults.
Fault(s)
The green "ON" LED is off,
no output voltage
Output voltage abnormally
low, charger operating
The battery is discharged
 Main power supply ok
 Charger operating
The "preheating" function
does not work (the yellow
"PRE" LED does not light
up)

6. EC Declaration of conformity

Name and address of manufacturer: SDMO, 12 bis rue de la Villeneuve, CS 92848, 29228 BREST CEDEX 2, FRANCE.
Description of the equipment
Make
Type
G. Le Gall, the manufacturer's authorised representative, hereby declares that the product conforms to the following EU
Directives:
2006/42/EC / Machinery Directive.
2006/95/EC / Low Voltage Directive.
2004/108/EC / Directive on Electromagnetic Compatibility.
2000/14/EC / Directive relating to the Noise Emission of Outdoor
Equipment.
Type
Sound power level
guaranteed (Lwa):
dB(A).
Rated output: kW
(LPG)
Possible cause(s)
No 230VAC power supply
Upstream fuse or circuit breaker open
Faulty (internal) FS fuse
Battery has completely discharged, the charger
current is limited
Faulty F2 fuse
C27 connector not connected properly
Figure 5.4: Battery charger fault finding table
Generating set
SDMO
RES9.5EC – RES13EC – RES18EC
RES12TEC – RES16TEC
RES9.5EC
RES13EC
87
7.5
Check the mains power supply and the
condition of the protective devices. Check the
FS (1A-T) internal fuse
Check the battery voltage with the battery
disconnected → 13.2VDC
Wait until the battery has recharged (the voltage
should gradually increase)
Check the condition of the battery
Check the battery connections (+ / - polarities)
Replace the F2 (5A-T) fuse
If the fault persists, replace the charger.
Check the voltage on the central terminal of the
C27 connector: it should be +12VDC between
this terminal and negative polarity.
For the directive 2000/14/EC
Notified body:
CETIM
BP 67
Compliance procedure: Appendix VI.
RES18EC
RES12TEC
89
90
10.5
14
05/2010 - G. Le Gall
73/73
Corrective measure(s)
F60304 – SENLIS.
RES16TEC
89
90
9.3
12.9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Res 13ecRes 18ecRes 12tecRes 16tec

Tabla de contenido