Message.
Not used
NONE
Output for 24Vdc max 5W power supply for accessories.
24V
This setting can only be used on outputs that are powered.
Output for 24Vdc max 5W power supply for controlled safety devices (the output is switched off
during the test if the safety device auto-test is enabled (SA.10). Use this type of output also for
checking the switching off of accessories with the energy-saving function active (EX.10).
24V_TEST
This setting can only be used on outputs that are powered.
In the case of control of safety devices, these must be wired and aligned before learning the
stroke (SE.03).
N.O. contact. Output for M1 motor electric lock.
ELOCK_M1
N.O. contact. Output for M1 motor inverted electric lock (for example for operating the electromagnet
ELOCK_INV_M1
of the barriers).
"Boost" power supply output for powering the DEA electric lock item 110.
ELOCK_BOOST_M1
This setting can only be used on outputs that are powered.
N.C. contact. (SAS_OUTPUT): If connected to STOP / SAS_INPUT on a second control unit, it triggers
the "bank door" mode (disabling of the opening of the second door until the fi rst has re-closed
WARN_FIX
SAS_OUTPUT
completely).
N.O. contact. (WARN_FIX): Operates as a steady open gate indicator.
Warning light gate indicator. Slow fl ashing output during opening and fast during closing, always
WARN_INT
ON with gate open, always OFF only at the end of a closing manoeuvre.
N.O. contact. Steady warning light output.
FLASH_FIX
N.O. contact. Intermittent warning light output.
FLASH_INT
Output for controlling the courtesy light.
The output is active while the motors are running plus an additional time governed by the COURTESY
COURTESY
time parameter (tI.07). The output can also be activated by a COURTESY_IN command.
C3 connector for LED module always acts like a COURTESY output.
N.O. contact. The contact closes for 3 seconds at the start of each manoeuvre.
MINUTERIE
N.C. contact. The contact always remains open and closes when a manoeuvre fails to start due to
a safety input (PHOTO, SAFETY, STOP) being active. The contact opens again when a subsequent
ALARM
attempt to start a manoeuvre succeeds. If there is no power, the contact is closed and can thus be
used to generate an alarm.
AUX_1_OUT_INPULS
N.O. contact. Output controlled by the AUX_1_IN / AUX_2_IN input in impulse mode.
AUX_2_OUT_INPULS
AUX_1_OUT_STEP
N.O. contact. Output controlled by the AUX_1_IN / AUX_2_IN input in step-by-step mode.
AUX_2_OUT_STEP
N.O. contact. Output controlled by the AUX_1_IN / AUX_2_IN input in timer-controlled mode (the
AUX_1_OUT_TEMP
AUX_2_OUT_TEMP
value set through parameters tI.16 and tI.17 indicates the switch-off delay in seconds).
OUTPUTS (OUT / EXP_OUT)
Description
NET724 EVO
37