NET724 EVO
TEST parameters (
tE.01
Control board input status visualization
Allows for viewing the status of inputs for the control board. An off segment corresponds to an open segment,
while an on segment is associated with a closed contact.
tE.02
Expansion board input status visualization
Allows for viewing the status of inputs for the expansion board. An off segment corresponds to an open segment,
while an on segment is associated with a closed contact.
tE.03
Manoeuvre counter status visualization
Allows for viewing the total number of manoeuvres completed by the control unit.
The display will show the word "tCYC" with the relative value, followed by the word "MULt" with the relative value of
the multiplier. To calculate the number of manoeuvres, the two values must be multiplied.
E.g.: tCYC=120, MULt=10; 120x10=1200 manoeuvres completed
tE.04
Not Used
tE.05
Automatic opening time (TAA)
Adjusts the time for automatic opening TAA
10 COMMISSIONING
The testing operation is essential in order to verify the correct installation of the system. DEA System wants to summarize
the proper testing of all the automation in 4 easy steps:
Make sure that you comply strictly as described in paragraph 1 "WARNINGS SUMMARY";
Test the opening and closing making sure that the movement of the leaf match as expected. We suggest in this regard to
perform various tests to assess the smoothness of the gate and defects in assembly or adjustment;
Ensure that all safety devices connected work properly;
Perform the measurement of impact forces in accordance with the standard EN12445 to fi nd the setting that ensures
compliance with the limits set by the standard EN12453.

11 PRODUCT DISPOSAL

DISASSEMBLY
The automation unit must be dismantled by qualifi ed personnel, in accordance with the current accident prevention
and safety regulations, and with reference to the installation instructions, but in the reverse order. Before initiating the
disassembly operations, disconnect the electrical power and make sure it cannot be reconnected.
DISPOSAL
The automation unit must be disposed of in accordance with the current local and national waste disposal regulations.
The product (or its individual parts) must not be disposed of together with other household waste materials.
WARNING In compliance with EU Directive 2012/19/EU on waste electrical and electronic equipment (WEEE), this
electrical product should not be treated as municipal mixed waste. Please dispose of the product and bring it to the
collection for an appropriate local municipal recycling.
52
)
Default
Default
TYPE 00
TYPE 04
000
000
• 000: Disabled
• >000: Active for the set time
(1s..................255s)