Descargar Imprimir esta página

Dea NET724 EVO Instrucciones De Uso Y Advertencias página 45

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 107
SY.08
NET-EXP enabling
NET-EXP expansion board enabling:
Warning: by default the expansion board is disabled.
Warning: if a settings default is performed, remember to set the parameters
correctly.
SY.09
Save position
Saving of the gate's position in the
memory in case of a power outage.
Warning:
To
parameter, also check the "RESP and
stop management" function (Mo.17).
SY.10
Not Used
SY.11
Not Used
SY.12
Type comunication port U1
Activates the serial communication in U1 port (if available on the board) or
in S1 (available in art.485/3-EXP).
Warning: It is not possible to occupy both ports at the same time.
SY.13
Not Used
SY.14
Type comunication port U3
Activates the serial communication in U3 port (if available on the board) or
in S3 (available in art.485/3-EXP).
Warning: It is not possible to occupy both ports at the same time.
INPUT / OUTPUT parameters (
Io.00
Restoration of the "I/O" (input/output) settings
Restores the inputs and outputs to the default values for the set TYPE (on the control unit and NET-EXP).
Enter in Io.00 with the [OK] button: dEF2 will appear fl ashing; press and hold the [OK] button until dEF2 stops
fl ashing; Release the [OK] button.
Io.01
INPUT 1
Io.02
INPUT 2
Io.03
INPUT 3
Io.04
INPUT 4
• 000: NONE
• 001: START
• 002: PED
• 003: OPEN
• 004: CLOSE
• 005: OPEN_PM
• 006: CLOSE_PM
• 007: OPEN_INT
Io.05
...
Not Used
Io.10
Io.20
Operation of the button [↑]
Io.21
Operation of the button [↓]
• 000: NONE
• 001: START
• 002: PED
• 003: OPEN
• 004: CLOSE
• 000: RESP_ON = At the switch-off , the gate's position is not saved in the
memory. The RESP is performed at the subsequent manoeuvre.
complement
this
• 001: RESP_OFF = At the switch-off , the gate's position is saved in the
memory. The RESP is not carried out.
)
• 008: OPEN_EXT
• 009: OPEN_STOP
• 010: AUX_1_IN
• 011: AUX_2_IN
• 012: COURTESY_IN
• 013: Non Utilizzato
• 014: Non Utilizzato
• 015: Non Utilizzato
• 005: OPEN_PM
• 006: CLOSE_PM
• 007: OPEN_INT
• 008: OPEN_EXT
• 009: OPEN_STOP
000
• 000: Disabled
• 001: Enabled
000
000
• 000: U1_UART
• 001: S1_RS485
000
• 000: U3_UART
• 001: S3_RS485
Default
TYPE 00
017
001
013
015
• 016: STOP / SAS_INPUT
• 017: SWO_1
• 018: Non Utilizzato
• 019: SWC_1
• 020: Non Utilizzato
• 021: PHOTO_1
• 022: PHOTO_2
• 023: SAFETY_1
000
000
• 010: AUX_1_IN
• 011: AUX_2_IN
• 012: COURTESY_IN
NET724 EVO
000
001
000
000
Default
TYPE 04
017
001
000
000
• 024: SAFETY_1_8k2
• 025: SAFETY_2
• 026: SAFETY_2_8k2
• 027: SAFETY_INHIBITION
• 028: EMERGENCY_IN
• 029: Non Utilizzato
• 030: RESET
• 031: MANEUVER_INHIBITION
003
004
43

Publicidad

loading

Productos relacionados para Dea NET724 EVO