tI.20
Delay on "CLOSE IMMEDIATELY"
Allows for setting after how many seconds the automatic re-closing of the
"close immediately" function occurs (SA.05).
EXTRA parameters (
EX.01
Condominium function
Allows for disabling the opening and closing command inputs during
opening and the automatic closing time.
EX.02
Not Used
EX.03
Not Used
EX.04
Not Used
EX.05
Not Used
EX.06
"STEP-BY-STEP" enabling
Selection of the "reversal" mode (during the manoeuvre a command impulse
reverses the direction of motion) or "step-by-step" (during the manoeuvre a
command impulse stops the movement. The subsequent impulse restarts
the movement in the opposite direction).
EX.07
Manual unlocking facilitation with gate closed
If=0, the function is disabled.
If≠0, after the detection of the closing stop, 1 motor carries out a brief
reversal to release the pressure on it and facilitate manual unlocking. The
set value indicates the duration of the reversal.
EX.08
Manual unlocking facilitation with gate open
If=0, the function is disabled.
If≠0, after the detection of the opening stop, 1 motor carries out a brief
reversal to release the pressure on it and facilitate manual unlocking. The
set value indicates the duration of the reversal.
EX.09
Not Used
EX.10
Energy Saving
Function for energy saving when there is an emergency battery kit or a power supply system based on solar panels.
When the Energy Saving function is active, the display is off and shows the "- -" symbol every 10s. The function can
be set to 3 levels:
• 000: "Energy saving" not active;
• 001: "Energy saving" active: switches off all outputs except for the Vaux 24V fi xed output;
• 002: "Energy saving" active: switches off all outputs except for the Vaux 24V fi xed output; moreover, any STATUS-
type outputs are kept active.
Warning: with "Energy saving" active the SAS function is not available.
EX.11
SAS function
Activation of the SAS function (only for SAS_OUTPUT outputs): the SAS
output is connected to a STOP / SAS_INPUT input of a second control unit,
triggering the "bank door" operating mode (opening of the second door is
disabled as long as the fi rst door is not fully closed).
If this parameter is enabled, following a reset it performs an automatic RESP
during which the SAS output does not activate. If limit switches are present
and are crushed after a reset, the RESP will not be carried out.
Warning: if both leaves are manually unlocked and shifted from the closing
position, the interlock condition is created. It will then be necessary to
manually close at least one of the two leaves.
Warning: the STOP / SAS_INPUT input must be activated by a voltage-free
clean contact output, such as that of a NET-EXP expansion card output or a
relay.
Warning: in case of RESP, the SAS function must necessarily be linked to a
search for the reference / stop towards closure. So it works with the values
of Mo.17 = 001, 003, 005.
50
)
001
001
(1s..................10s)
Default
Default
TYPE 00
TYPE 04
000
000
• 000: Disabled
• 001: Active only on opening
• 002: Active on opening and during
automatic close time
001
001
• 000: Reversal
• 001: Step-by-Step with START and
PED
• 002: Step-by-Step with START, PED
and OPEN/CLOSE
000
000
• 000: Unlocking facilitation deactivated
• >000: Unlocking facilitation activated
with duration equal to:
(1x25ms.........20x25ms)
(1x25ms.........40x25ms - ONLY TYPE 00)
000
000
• 000: Unlocking facilitation deactivated
• >000: Unlocking facilitation activated
with duration equal to:
(1x25ms.........20x25ms)
(1x25ms.........40x25ms - ONLY TYPE 00)
000
000
000
000
• 000: Disabled