9 "PRO" PARAMETERS LIST
SETUP parameters (
SE.03
Motor stroke learning
Start the stroke learning procedure:
Press [OK] once: CL-1 will be displayed;
CL-1: bring the motor to the desired closing point using the [+] and [-] buttons. Confi rm the position by pressing
[OK] until OP-1appear on the display;
OP-1: bring the motor to the desired opening point using the [+] and [-] buttons. Confi rm the position by pressing
[OK] until CLOS fl ashes then release the button.
The CLOS message may remain on the display for a variable time, after which the motor will start an automatic
maneuver (close-open) to memorize the stroke and forces. At the end of the procedure SE.03 reappears.
Attention: If there are wired limit switches, the motor will stop automatically during the positioning phase when a
limit switch is reached. It will however be necessary to confi rm the position with the [OK] button to continue.
SE.04
Motor running direction
Motion direction reversal: If=1 automatically reverses the motor's open/
close outputs, so the wiring does not have to be modifi ed manually if the
gearmotor is installed in the inverted position with respect to the standard.
Warning: By changing this parameter the limit switches will NOT be inverted
if present.
Warning: When this parameter is modifi ed, a new motor stroke learning
procedure must be carried out (SE.03).
RADIO parameters (
rA.01
Deletion of all remote controls in memory
- Briefl y press [OK] once: CANC will appear fl ashing;
- Press and hold [OK]: the word CANC will become steady; After roughly 5 s, when rA.01 reappears, release the [OK]
button (all remote controls will have been deleted).
rA.02
Learning of remote controls
- Press [OK] once: LEAR will appear for roughly 10 s;
- while the word LEAR is displayed, press any button of the remote control to be memorised;
- If the memorisation succeeds, the display will show the position assigned to the new saved remote control (e.g.
r000, r001, etc.).
rA.03
Searching and deleting a remote control
- briefl y press [OK] once;
- use the [+] and [-] buttons to reach the position assigned to the remote control that must be deleted;
- press [OK] and hold it for roughly 5s until "r- - -" appears on the display (the selected remote control has been
deleted);
- wait for the procedure to end (rA.03 will appear once again).
Warning: if there are no remote controls memorised, by accessing the parameter the word "no-r" will appear on
the display.
rA.04
Radio coding
• 000: HCS FIXED CODE
• 001: HCS ROLLING CODE
Warning: if the type of encoding must be varied and only if the memory already contains remote controls with
diff erent codes, the memory deletion procedure (rA.01) must be carried out AFTER setting the new code.
rA.05
Remote control button 1
rA.06
Remote control button 2
rA.07
Remote control button 3
rA.08
Remote control button 4
• 000: NONE
• 001: START
• 002: PED
• 003: OPEN
• 004: CLOSE
)
)
• 002: DIP SWITCH (HT12)
• 003: DART
• 005: Not Used
• 006: Not Used
• 007: OPEN_INT
• 008: OPEN_EXT
• 009: OPEN_STOP
NET724 EVO
Default
Default
TYPE 00
TYPE 04
000
000
• 000: Standard installation
• 001: Reversed installation
Default
Default
TYPE 00
TYPE 04
000
000
001
001
000
000
000
000
000
000
• 010: AUX_1_IN
• 011: AUX_2_IN
• 012: COURTESY_IN
41