Descargar Imprimir esta página

Dea NET724 EVO Instrucciones De Uso Y Advertencias página 47

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 107
MOVEMENT parameters (
Mo.01
Slow down speed in opening
Adjustment of the motor speed during the slow phase on opening.
Mo.02
Maximum speed in opening
Adjustment of the motor speed during the opening movement.
Mo.03
Acceleration distance on opening
Refers to a distance defi ned in % of the total path (value <30%) within which
the starting acceleration is created from an opening command. A small
value corresponds to a very high ramp.
Mo.04
Opening speed transition space
It expresses a space defi ned in % of the total stroke (value <30%) within
which the automation must slow down to the deceleration speed. The end
of this section is calculated starting from the point where the Mo.05 space
starts.
Mo.05
Slow down duration in opening
Refers to a space defi ned in % on the total path (value <30%). It represents the
last section completed by the automation during the opening manoeuvre.
Mo.06
Slow down speed in closing
Adjustment of the motor speed during the slowdown phase on closing.
Mo.07
Maximum speed in closing
Adjustment of the motor speed during the closing movement.
Mo.08
Acceleration distance on closing
Refers to a distance defi ned in % of the total path (value <30%) within which
the starting acceleration is created from an closing command. A small value
corresponds to a very high ramp.
Mo.09
Closing speed transition space
It expresses a space defi ned in % of the total stroke (value <30%) within
which the automation must slow down to the deceleration speed. The end
of this section is calculated starting from the point where the Mo.10 space
starts.
Mo.10
Slow down duration in closing
Refers to a space defi ned in % of the total path (value <30%). It represents
the last section completed by the automation during the closing manoeuvre.
Mo.11
Stop Intensity
Adjusts how quickly the motor drops to 0 (zero) speed in the event of a stop
or movement reversal.
Aff ects stops generated by:
- movement commands (START, OPEN, CLOSE, PED, etc.);
- PHOTO or STOP type input activation.
It does not aff ect stops generated by:
- arrival on limit switch or on memorized point;
- emergency reversal (internal obstacle detection or SAFETY type input
activation).
Note: Higher values = faster stop; Low values = slower stop.
Warning: To prevent excessive stresses that could compromise the proper
functioning of the automation, it is recommended to always take into
account the possible inertia of the door, avoiding setting too high values in
the presence of important masses.
Mo.12
Percentage of pedestrian opening
Adjustment of the distance of the pedestrian opening movement.
Mo.13
Motor 1 obstacle detection sensitivity in opening
Obstacle detection sensitivity adjustment for Motor 1 in opening, based
on the amount of force required to trigger the obstacle detection. Higher
number is less sensitive.
Mo.14
Motor 1 obstacle detection sensitivity in closing
Obstacle detection sensitivity adjustment for Motor 1 in closing, based
on the amount of force required to trigger the obstacle detection. Higher
number is less sensitive.
)
NET724 EVO
Default
Default
TYPE 00
TYPE 04
040
055
0%..................100%
100
100
0%..................100%
010
010
0%..................30%
010
010
0%..................30%
010
010
0%..................30%
040
020
0%..................100%
100
075
0%..................100%
010
010
0%..................30%
010
010
0%..................30%
010
010
0%..................30%
020
020
0%..................50%
030
050
0%..................100%
050
040
0%..................100%
050
040
0%..................100%
45

Publicidad

loading

Productos relacionados para Dea NET724 EVO